Critical Alert Message for DS3500 – not on preferred path


Sul nostro apparato di virtualizzazione (un DS3500 IBM) è comparso questo errore

Node ID: DS3500_XX
Host IP Address:
Host ID: Out-of-Band
Event Error Code: 4011
Event occurred: mar 20, 2015 5:15:55 PM
Event Message: Logical Drive not on preferred path due to ADT/RDAC failover
Event Priority: Critical
Component Type: Controller
Component Location: Enclosure 99, Slot A

Node ID: DS3500_XX
Host IP Address:
Host ID: Out-of-Band
Event Error Code: 282b
Event occurred: mar 20, 2015 5:11:36 PM
Event Message: Drive expansion enclosure path redundancy lost
Event Priority: Critical
Component Type: Enclosure
Component Location: Enclosure 99

Node ID: DS3500_XX
Host IP Address:
Host ID: Out-of-Band
Event Error Code: 1710
Event occurred: mar 20, 2015 5:11:20 PM
Event Message: Controller wide port has gone to failed state
Event Priority: Critical
Component Type: Controller
Component Location: Enclosure 99, Slot B

Node ID: DS3500_XX
Host IP Address:
Host ID: Out-of-Band
Event Error Code: 1710
Event occurred: mar 20, 2015 5:11:20 PM
Event Message: Controller wide port has gone to failed state
Event Priority: Critical
Component Type: Controller
Component Location: Enclosure 99, Slot A

In pratica in un momento di affanno il sistema ha switchato le partizioni logiche su una rotta non predefinita.
Per ripristinare l’errore si va sul DS Storage Manager si deve fare doppio click sullo storage incriminato
Immettere la password di sistema
Andare quindi sul menù Storage –> Logical Drive –> Advanced–> Redistribuite logical drive
Verrà presentato un messaggio di avvertim,ento con possibili perdite di dati, clickare ok comunque.
il sistema si riallinea correttamente.

Critical Alert Message for DS3500 – not on preferred path ultima modifica: 2015-03-20T19:21:08+00:00 da Enrico